This page was exported from Exam for engine [ http://blog.test4engine.com ] Export date:Mon Nov 18 2:45:39 2024 / +0000 GMT ___________________________________________________ Title: [May 13, 2022] Lesson Brilliant PDF for the NS0-516 Tests Free Updated Today [Q15-Q33] --------------------------------------------------- [May 13, 2022] Lesson Brilliant PDF for the NS0-516 Tests Free Updated Today Get New 2022 Valid Practice NCIE SAN E-Series NS0-516 Q&A - Testing Engine NetApp NS0-516 Exam Certification Details: Exam Price$150 USDExam NameImplementation Engineer SAN Specialist E-SeriesExam RegistrationPEARSON VUEPassing Score75%Duration90 minutesExam CodeNS0-516 NCIE SAN Specialist E-SeriesSample QuestionsNetApp NS0-516 Sample Questions   QUESTION 15What is represented by the Headroom graph on the SANtricity System Manager performance tab?  the percentage of I/O associated with the backend disk drives  the remaining performance capability of the physical objects in the storage system  the percentage of CPU processing capacity that is being used by the operations on the system  the resources that are being consumed by a defined workload QUESTION 16Synchronous mirroring requires what type of connection between storage systems? (Choose the best answer.)  FC  SAS  iSCSI  InfiniBand QUESTION 17Which masking functions should you implement for each column to meet the data masking requirements?To answer, select the appropriate options in the answer area. NOTE: Each correct selection is worth one point. QUESTION 18Which object provides read/write access to a Snapshot image?  Snapshot group  Base volume  Snapshot repository  Snapshot volume QUESTION 19A junior administrator recently made changes to an E-Series system. As a result of these changes, the management host lost the ability to manage the E-Series system through in-band management, but the host still has access to the E-Series data volumes.In this scenario, what caused this issue?  The access volume was un-mapped  The management IPs were changed  The ownership of the management host’s volumes changed  Auto Load Balancing was disabled QUESTION 20A company is using the Federal Information Processing Standard (FIPS) on all volume groups. However, one volume group failed a security audit.In this scenario what would cause a volume group to fail the security audit?  An FDE drive was added as a spare in the volume group  Data Assurance was changed to “disabled” for the volume group  The Secure Erase operation was applied to the volume group disks  Connectivity to the key server was interrupted QUESTION 21You are troubleshooting a customer issue on their E-Series system. You need information on the volume configuration of the customer’s system.In this scenario, which log would you download to get the required information?  Trace Buffers  Support Data  Health Image  IO Path Statistics QUESTION 22In-band communication occurs between which entities?  The management host and the Ethernet management ports  The ESM and the I/O host  One of the data I/O host’s Ethernet port 1 and the expansion shelves  One of the data I/O hosts and the controllers QUESTION 23Exhibit:You ordered a NetApp E2812 Duplex 16GB 10GbE Base-T system.Referring to the exhibit, what is the maximum number of 10GbE Base-T ports available to be used?  6  8  4  12 QUESTION 24Which three are techniques for troubleshooting the management connection? (Choose three.)  Check the Ethernet cables (out-of-band).  Restart the agent (in-band).  Ping the controller ports (out-of-band).  Delete the EMWdata_vxx.bin file (in- and out-of-band). QUESTION 25A customer is experiencing performance issues on their NetApp E-Series system that is running with iSCSI host interface cards (HICs).In this scenario, in which two locations in the GUI would you go to find detailed statistics for the ISCSI connections on this system? (Choose two.)  Support -> Support Center -> Diagnostics -> View iSCSI Statistics  Home -> View Performance Details  Support -> Support Resources -> Storage Array Profile  Settings -> System -> View ISCSI Statistics QUESTION 26When data is written to a snapshot, volume is stored __________. (Choose the best answer.)  on the base volume for that snapshot  on the repository area associated with the snapshot’s corresponding image  on the repository associated with the snapshot volume  on the common repository for the snapshot group  on a hot spare drive QUESTION 27Which two steps are required to enable multifactor authentication on an E-Series system? (Choose two)  Test SSO login  Configure LDAP  Map roles  Configure In-Band Management QUESTION 28Which three methods can be used to increase the space available to clients? (Choose three.)  Increase volume segment size  Convert RAID-6 volume group to RAID-5  Create new volume groups from unconfigured capacity  Fill empty drive slots in the array  Replace some HDD with SSD QUESTION 29A customer is configuring an EF570 system on an internal network. Due to security concerns, the network does not have Internet access. The customer wants to regularly send standard support data to NetApp.In this scenario, what should the customer do to accomplish this task?  Enable AutoSupport with a set interval and with the store locally option selected, manually move the data to a server with Internet access, and then send the data to NetApp.  Open a support ticket with NetApp to enable AutoSupport local functionality, manually move the data to a server with Internet access, and then send the data to NetApp.  Set up a script to initiate Collect Support Data on a set interval, manually move the data to a server with Internet access, and then send the data to NetApp.  Set up a script to initiate Collect Support Data, remove the extra log files, manually move the data to a server with Internet access, and then send the data to NetApp. QUESTION 30According to NetApp recommended practices, is this E2712 storage system cabled for a dual-stack configuration? If not, why?  No. The cabling to the disk shelves is coming from the host ports.  No. The controllers are only cabled to one “stack.”  No. The cabling has split the top-down-bottom-up configuration.  Yes. The cabling configuration is correct. QUESTION 31A company has just installed a NetApp EF600 storage array with an initial drive count of 12. A disk pool is created using all 12 disks. Benchmark testing now shows that system performance is far less than expected. Metrics show a very unbalanced use of the two PcIe busses and drives.In this scenario, which action addresses this problem?  Dynamically convert the volumes from RAID 10 to RAID 5.  Adjust cache block sizes to 8k.  Build two equally sized pools during disk pool creation.  Insert six drives into the first 12 slots and six drives into the last 12 slots. QUESTION 32A customer intends to use an E2812 system without expansion shelves. The specification for their Windows host requires that six E-Series data volumes be used.In this scenario, how should the system be configured?  one DDP with all the volumes  three DDPs with the volumes divided equally  one DDP for each volume  two DDPs with the volumes divided equally QUESTION 33The out-of-band connection is an Ethernet connection from the storage manager host to the LAN, and from the LAN to which location?  port 1 of the I/O host  port 2 of the ESM  port 1 of the controller  port E of the controller  Loading … NetApp NS0-516 Exam Topics: SectionObjectivesHost Side-Describe the different host connection options for E-Series systems.-Describe how to configure hosts for multipathing.Protection-Describe how Data Assurance with media scan protects your data.- Describe SANtricity data protection features.Troubleshooting-Demonstrate the steps for troubleshooting an E-Series system.-Demonstrate how to analyze multipathing issues between a host and an E-Series system.Hardware-Describe the hardware components in an E-Series storage system.-Describe Fibre Channel, Ethernet, Infiniband and SAS cabling.-Describe the appropriate tasks for adding additional storage to an E-Series system.-Describe drive encryption features.Management-Describe the administrative tasks for managing E-Series systems with SANtricity System Manager.-Describe the management security features in SANtricity System Manager and SANtricity Unified Manager.-Describe when and how to configure and use SANtricity Unified Manager.Documentation-Describe the process of reviewing and preparing a site for implementation of E-Series.-Describe the information you give a customer after deploying a solution.SAN-Describe the end-to-end network configuration for Fibre Channel and Ethernet.Toolbox-Describe the tools required to design and implement an E-Series solution.   NS0-516 Dumps PDF - 100% Passing Guarantee: https://www.test4engine.com/NS0-516_exam-latest-braindumps.html --------------------------------------------------- Images: https://blog.test4engine.com/wp-content/plugins/watu/loading.gif https://blog.test4engine.com/wp-content/plugins/watu/loading.gif --------------------------------------------------- --------------------------------------------------- Post date: 2022-05-13 11:14:39 Post date GMT: 2022-05-13 11:14:39 Post modified date: 2022-05-13 11:14:39 Post modified date GMT: 2022-05-13 11:14:39