This page was exported from Exam for engine [ http://blog.test4engine.com ] Export date:Mon Nov 18 3:36:27 2024 / +0000 GMT ___________________________________________________ Title: Free H19-402_V1.0 Exam Braindumps - New 2024 Huawei Pratice Exam [Q215-Q236] --------------------------------------------------- Free H19-402_V1.0 Exam Braindumps - New 2024 Huawei Pratice Exam Practice Test for H19-402_V1.0 Certification Real 2024 Mock Exam NEW QUESTION 215 UPS5000-E has no built-in transformer.  True  False NEW QUESTION 216 UPS5000-E has a wide voltage and frequency input range, which can be used in harsh power grid environments and extend battery life. What is the input voltage range of UPS5000-E at full load?  138-485V  305-485V  105-485V NEW QUESTION 217 What are the column-wrapping scenarios of FM2000? (Multiple choice)  Pillars in the channel  Column in the cabinet  Columns spanning cabinets and aisles  Columns at both ends of the cabinet NEW QUESTION 218 What is the size of the screen of the FusionModule2000 air conditioner?  10 inches  7 inches  5 inches  9 inches NEW QUESTION 219 The main input voltage range of UPS2000-G- (6K-20K) of each capacity model is 80V~280V, and the input frequency range is 40Hz-70Hz. The ultra-wide input range can effectively reduce the number of batteries switching, avoid high-fault areas, reduce battery charging and discharging times, and extend battery life.  True  False NEW QUESTION 220 Which of the following are the environmental parameter requirements for the main computer room of the data center?  Temperature 18~27C  Dew point temperature 5.5~15C  Relative humidity is not more than 60%  No condensation in the machine room  satisfies ABCD at the same time NEW QUESTION 221 FusionModule1000AV2R3 version supports customized VESDA system  True  False NEW QUESTION 222 What certifications does Huawei’s precision cabinet have? (Multiple choice)  Earthquake resistance  CE  UL  Thiel NEW QUESTION 223 UPS5000-A system, which of the following battery configurations is unreasonable?  32 12V batteries  37 12V batteries  40 12V batteries  42 12V batteries NEW QUESTION 224 What kind of access control system can the rear door of the FusionModule2000 cabinet support?  Mechanical combination lock  IC card access control  Three-in-one access control  None of the above NEW QUESTION 225 FusionModule800 can only support downlink routing  True  False NEW QUESTION 226 The NetEco6000 management system can provide a temperature cloud map function to identify hot and cold spots in the computer room. How many layers of temperature cloud maps does the temperature cloud map support? (Multiple choice)  Single layer  Double layer  Three layers  Four layers NEW QUESTION 227 FusionModule800 has the function of automatic start-up of civil air conditioner when receiving a call  True  False NEW QUESTION 228 UPS5000-E can maintain high efficiency in a wide load range and effectively reduce losses. Among them, the efficiency can reach 96% at 40% load and 95% at 20% load. What is the efficiency in ECO mode?  97%  99%  96%  98% NEW QUESTION 229 When using ModBUS to remotely manage UPS500-E, which option should be selected?  No  RS232 to USB interface  ModBUS card NEW QUESTION 230 When the NetEco management system intervenes in third-party devices outside the micromodule, what kind of monitoring hardware is usually used to access it?  ECC500 collector  ECC800 Collector  Serial port server  None of the above NEW QUESTION 231 What kind of inlet and outlet wiring methods can the FusionModule2000 integrated power distribution cabinet implement?  Down-in and down-out  Upper inlet and outlet  Up-line in and down-line out  Lower inlet and upper outlet NEW QUESTION 232 The number of batteries in traditional UPS cannot be adjusted, and the battery maintenance cost is high. If one battery is damaged, the entire battery group may need to be replaced. The number of batteries in UPS5000-A can be adjusted, so what is the adjustable range?  30-40  34-40  36-40  32-40 NEW QUESTION 233Which of the following alarm functions does the main circuit of PDU800 power distribution cabinet have? (Multiple choice)  Current high value over-limit alarm  Overvoltage alarm  Main circuit power failure  Frequency Abnormality  Undervoltage alarm NEW QUESTION 234 Considering the low load rate of the UPS system, the UPS5000-E is designed with an intelligent sleep function, which can increase the system load rate and keep the system running efficiently. When the UPS5000E is in intelligent sleep mode, how many power modules are redundant?  2  1  0 NEW QUESTION 235 NetEco6000 management system supports virtualization deployment and adapts to the future cloud computing rhythm.  True  False NEW QUESTION 236 Which of the following UPS does not have a neutral line?  UPS5000-H  UPS5000-E  galaxy5000  APM150  Loading … Prepare For Realistic H19-402_V1.0 Dumps PDF - 100% Passing Guarantee: https://www.test4engine.com/H19-402_V1.0_exam-latest-braindumps.html --------------------------------------------------- Images: https://blog.test4engine.com/wp-content/plugins/watu/loading.gif https://blog.test4engine.com/wp-content/plugins/watu/loading.gif --------------------------------------------------- --------------------------------------------------- Post date: 2024-10-22 11:56:40 Post date GMT: 2024-10-22 11:56:40 Post modified date: 2024-10-22 11:56:40 Post modified date GMT: 2024-10-22 11:56:40